The commands in the Mass MEMory subsystem contain functions that provide access to the instrument setup and data storage.
:MMEMory:LOAD:LIMit <string>,<string>,<string>
Title
Load Limit From File
Description
This command loads limit data from the limit file specified by file name. The three parameters for this command are label, file name and current storage location. File name is relative file path to the current storage location including the file name to be loaded and it should not be empty. Current location can be an external device path. Current location defaults to the internal memory, if an empty string is passed. Currently label is not being used. Send an empty string.
Load data from RAM to a file. This command takes three parameters 1. data block size: that needs to be loaded in bytes (must be a word aligned) 2. offset: in bytes from start of RAM address to load from 3. filename: name of the file without the full path. This is the destination file where the contents of RAM are copied over
Parameter(s)
<numeric_value>,<numeric_value>,<string>
:MMEMory:STOEvent:CLEarall
Title
Clear All Save On Event
Description
Turns off all save on event types that are active.
:MMEMory:STOEvent:EOSWeep:MODE CONTinuous|SINGle
:MMEMory:STOEvent:EOSWeep:MODE?
Title
End of Sweep Save On Event Mode
Description
Specifies the stop mode of the end of sweep save on event system. Setting the value to CONTinuous will cause the instrument to keep saving traces at the completion of every valid sweep. Setting the value to SINGle will trigger a save trace on the next complete valid sweep and then automatically turn the end of sweep save on event feature OFF.
Parameters:
CONTinuous|SINGle
Default Value:
CONTinuous
:MMEMory:STOEvent:EOSWeep[:STATe] <boolean>
:MMEMory:STOEvent:EOSWeep[:STATe]?
Title
End of Sweep Save on Event State
Description
Turn the end of sweep save on event ON or OFF. Turning the feature on will cause the instrument to automatically save a trace whenever a sweep completes.
A common cause of the command failure is not having enough space available on the storage location. Use :MMEMory:CATalog:DIRectory query command to retrieve the total space available on the storage location.
Parameters:
<boolean>
Default Value:
OFF
:MMEMory:STOEvent:LIMit:INTerval <numeric_value> {US | MS | S | MIN | HR}
:MMEMory:STOEvent:LIMit:INTerval?
Title
Limit Save On Event Interval
Description
Sets the time interval to keep saving after a limit line failure has occured when :MMEMory:STOEvent:LIMit:MODE is set to INTerval.
Specifies the stop mode of the limit save on event system. Setting the value to CONTinuous will cause the instrument to keep saving traces at every limit line failure. Setting the value to SINGle will trigger a save trace on the next limit line failure and then automatically turn the end of sweep save on event feature OFF automatically. Setting the value to INTerval will trigger a save on the next limit line failure and continue to save at every end of sweep until the set time interval has expired.
Syntax:
CONTinuous|SINGle|INTerval
Default Value:
CONTinuous
:MMEMory:STOEvent:LIMit:PTRigger[:STATe] <0 | 1 | ON | OFF> :MMEMory:STOEvent:LIMit:PTRigger[:STATe]?
Title
Limit Pretrigger Save on Event State
Description
Turn the limit pre-trigger save on event ON or OFF. Turning the feature ON will cause the instrument to automatically save a trace captured prior to the limit line failure trace. The :MMEMory:STOEvent:LIMit[:STATe] and :INITiate:CONTinuous needs to be turned ON for the pre-trigger feature to apply.
A common cause of the command failure is not having enough space available on the storage location. Use :MMEMory:CATalog:DIRectory query command to retrieve the total space available on the storage location.
Parameter(s)
<0 | 1 | ON | OFF>
Query Return
0 | 1
Default Value
OFF
:MMEMory:STOEvent:LIMit[:STATe] <boolean>
:MMEMory:STOEvent:LIMit[:STATe]?
Title
Limit Save on Event State
Description
Turn the limit save on event ON or OFF. Turning the feature on will cause the instrument to automatically save a trace whenever a limit line failure occurs.
A common cause of the command failure is not having enough space available on the storage location. Use :MMEMory:CATalog:DIRectory query command to retrieve the total space available on the storage location.
Parameters:
<boolean>
Default Value:
OFF
:MMEMory:STORe:LIMit <string>,<string>,<string>
Title
Store Limit to File
Description
This command stores the limit data into the file specified by file name. The three parameters for this command are label, file name and current storage location. File name is relative file path to the current storage location including the file name to be saved and it should not be empty. Current location can be an external device path. Current location defaults to the internal memory, if an empty string is passed. Currently label is not being used. Send an empty string.
A common cause of the command failure is not having enough space available on the storage location.Use :MMEMory:CATalog:DIRectory query command to retrieve the total space available on the storage location.
Store data to RAM from a file. This command takes three parameters 1. data block size: that needs to be stored in bytes (must be a word aligned) 2. offset: in bytes from start of RAM address to store data at 3. filename: name of the file without the full path. Contents of this file will be copied over to RAM